Product Information
It is mainly used for the reciprocating impact compression fatigue test of foam polymeric materials to determine the thickness reduction value and hardness reduction value (residual deformation rate) of the sample, and thus the dynamic fatigue characteristics of the material can be understood.
Testing Standards
ISO 3385, ASTM D3574
Technical parameters
Control mode |
LCD Touch screen control |
Induction mode |
Precision load element |
Capacity |
200kg |
Unit switch |
Kg, N, LB |
Pressure plate |
overall diameter of 250 mm± 1 mm with a 25 mm± 1 mm radius at its lower edge, provided with a device for applying a maximum force of 750 N ± 20 N during one loading cycle |
Lower platform |
420×420mm, porosity diameter 6mm, spacing 20mm |
Maximum stroke |
200mm |
Test speed |
(70 ± 5) times/min (adjustable) |
Counter |
1-999,999cycles |
Power source |
Servo motor |
Transmission mode |
Precision ball screw |
Power source |
Single-phase, 220V, 50Hz/60Hz, 2.5A |
Weight |
90kg |
Dimension(L×W×H) |
600×500×800mm |