News
Home > News

The Latest Standards of Glow Wire Test Chamber Launched

Glow Wire Test Chamber with ICE standards is launched lately.Welcome all kinds of companies to come to consult.

1. Application
The Glow Wire Tester is designed to carry out fire hazard testing on electro technical products in accordance with the provisions of International standards.
• The control unit is supplied with all the controls and metering necessary to accurately set the temperature of the glow wire.  The wire current is continuously variable by means of the panel-mounted controller and is monitored by the built-in ammeter.
• A digital temperature indicator is fitted which, in conjunction with the thermocouple supplied, accurately measures the glow wire temperature.  The electrical circuit of the control unit is fully protected by fuses and a miniature circuit breaker and incorporates mains on/off switching and push button control of the output current. Self contained cabinet with large viewing window and dark colored interior.
2. Technical parameters
Glow wire  diameter 4mm±0.04mmNi/Cr(80/20), standard  
Temperature range 500 ~ 750℃±10℃;750 ~ 960℃±15℃
Thermocouple diameter 0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand temperature-40~ 1100°C
Searing Time 30s±0.1s (OMRON H5CN-XAN-Z digital timer, 0-9999s, preset table)
Light-off Time 0-999.9 s ± 0.1 s, automatic recording, manual timeout
Fire out time 0-999.9 s ± 0.1 s, automatic recording, manual timeout
Ironing into depth  7mm ± 0.5 mm
Sample pressure 1N ± 0.2 N
Test speed 18±3mm/s
Test background black background
Test process automatic control, independent convulsions
Chamber ≥0.5m
Control Using single chip microcomputer + touch screen control
Consult standards  

IEC60695 - 2 - 10 / 11 / 12 / 13、IEC60884-1、GB2099.1、IEC60335-1、GB4706.1、VDE0620
Power Supply AC 220V,50Hz

Related news
MSN

SKYPE