Home > Building Material Flammability Test Equipment > ASTM E648 Radiant Flooring Panel Apparatus
ASTM E648 Radiant Flooring Panel Apparatus
ASTM E648 Radiant Flooring Panel Apparatus
ASTM E648 Radiant Flooring Panel Apparatus
ASTM E648 Radiant Flooring Panel Apparatus
ASTM E648 Radiant Flooring Panel Apparatus

ASTM E648 Radiant Flooring Panel Apparatus

Product Model : SL-FL086
To measure the critical radiant flux of flame stop spreading horizontally, and smoke density of flooring material during test.
Detailed description
ASTM E648 Building Materials Flammability Tester Radiant Flooring Panel Apparatus
 
Application
To measure the critical radiant flux of flame stop spreading horizontally, and smoke density of flooring material during test.
 
Features
1. Blower for gas supply of radiant plate can supply gas continuously, while air compressor supply gas uncontinuously.
2. Heat Flux meter, portable water cooling system without running water supply.
3. Ventilation hood of stainless steel on the top of the chamber.
4. Inner chamber of Heat and corrosion resistant Aluminum silicate plate.
5. Heat resistant honeycomb ceramic thermal radiant plate 300mmX450mm, inclined at 30 degree.
6. T-shape porous burner with auto ignition system ignites the specimen with automatic push system.
7. Gas control board. Needle valve control the height of burner flame, MFC controls the gas flux and digital display.
8. Inverter control blower output, ventruri control the proportion of air and gas, and flame is stable, and accurate.
9. Porous calibration apparatus: adjust radiant plate output by turning upward, left or right.
10. IR radiometer shows the temperature of the radiant plate.
11. Optional smoke density testing system.
12. Optical system 2900 ± 100 K light advanced optical signal receiver.
13. integrated design with 19" PC of Lab view software.
14. Chimney with1pc thermocouple, and 1pc thermocouple inner Chamber controlled by software.
 
Standards
ISO 9239-1 reaction to fire test of flooring material, Part 1, measure the combustion performance of flooring material with radiant heat.
ISO 9239-2 reaction to fire test of flooring material, Part 2, measure the horizontal spread of flame, exposed to 25kw/m2 heat flux.
ASTM E 648 Standard test method for flooring covering system CHF with heat radiant energy source.
ASTM E 970 Standard test method for flooring material CHF of exposed attic floor insulation using heat radiant energy source.
NFPA 253 Standard test method for CHF of floor covering system with heat radiant energy source.
DIN 4102
 
Technical parameters
 Dimension testing chamber  2220(W)×1500(D)×2650(H)mm
 Control chamber  600(W)×600(D)×1600(H)mm
 Gas control chamber  600(W)×600(D)×1000(H)mm
 Power Supply  AC 220V, 50/60Hz, 25A
 Weight  220kg
 Air supply option propane  95%

 

Building Materials Flammability Tester Flooring Radiant Panel for Fire Testing for Standard ASTM E648